After that you need to insert the butane lighter into the gas tube. New models usually come with improved.


Gas Log Fireplace Repair Tips So Helpful This Link Is How To Troubleshoot When Your Fireplace Keeps G Gas Fireplace Gas Fireplace Logs Gas Fireplace Insert

While flame is still going put meter lids on the connectors of thermopile.

. Lightly sand away the carbon deposit until it looks clean again. 1- Make sure gas is off and system is cool. The red valve from your gas source to the internal workings of your fireplace is off.

Connect the new log sets gas line to the burner. If the gas fireplace shuts off after a few minutes its pretty much always going to be a pilot head issue or a valve issue. Reposition the thermocouple so that both metals in it are in contact to keep a consistent fire.

If they dont stay lit after cleaning try the air trick at least one more time. Then theres safety considerations. The drawback of a gas fireplace is that it can have technical problems you wont find in a wood-burning fireplace.

The butane lighter is located near the center of the gas logs. To test for leaks turn on your gas supply. Check the breaker box and reset any tripped breakers you run across.

You must read 0 initially. Take note that its the pilot head not the thermocouple. This is very important.

4- Using an Air Duster insert the flexible straw into either air intake hole make sure air is pointed towards the pilot opening. Gasfireplacerepair fireplacepilotlight pilotlightwontstaylitWe show how to easily fix a gas fireplace pilot light to stay lit. A gas log configuration to get an authentic look should be done according to the manufacturers directions and with care to make sure the gas source has plenty of airflow.

If ceramic you cant reasonably fix it. 2- Lightly brush off pilot opening around air intake. Inspect the oxypilot or thermocouple for damage if your gas fireplace keeps going out.

Re-test the Cleaned Thermopile When youre satisfied with the way the thermopile looks go ahead and re-ignite the pilot light. To quickly clean your thermopile turn off the gas supply. The multimeter should read 300 millivolts or higher.

Occasionally the sensors get a spec of dust on them and it causes them to shut down. 6 Sep 12 2012. The most common issues with a gas fireplace are.

Its either made of a ceramic or cast iron. Standard gas log sets are fairly simple. Put the logs back into place and wait about 10 minutes before relighting them.

If not then the entire piece may need to be replaced or you could be facing a different issue altogether. Again you may need to use a screwdriver or other tools to do this check your log set model for specific instructions. Pilot Light Failure Follow the manufacturers instructions to relight the pilot.

Make sure its on. If it goes out and I turn the. Dont skip this step.

Try to test your fireplace and see if the gas fireplace will stay on this time. If it reads less then the thermopile should be cleaned turn off the gas supply and use a stainless-steel brush with fine-grit sandpaper if the reading is still low then replace the thermopile. If this doesnt do the trick check your propane supply or ensure the natural gas lines to your home is operating correctly.

Gas logs provide the realistic look and feel of a wood-burning fire without the need to clean out ashes and replenish wood. Fireplaces Wood Burning and Heating Stoves Flues and Chimneys - Gas Fireplace blowing out then coming back on - I have a Superior gas fireplace DVR6 model. The main control valve can be tested by using a multimeter that determines its resistance.

Set your meter to VOLTS DC and range to mV millivolts. Much like cleaning the thermocouple you might want to start by cleaning your thermopile. How to Fix a Faulty Gas Fire Between the pilot supply pipe and the pilot burner theres a brass tail or connector.

Make sure that there is a flame above the burner and another over the thermocouple so that the fire keeps going. If you suspect the pilot light is being blown out close your flue or windows where too much air is coming in. Therell be a small hole on one side.

Is your propane or natural gas tank empty. If cast iron and you absolutely had to a good welder could fix it. Clean the internal threaded area where your thermocouple attaches to the valve.

Make sure theres no dust blocking this and clean if needed. 3- Blocked ODS openings will not operate properly. Here are the widely-used models and designs gas fireplaces use and what issues will arise with each of them.

A step by step tutorial showing how to remove and clean a blocked gas diffuser in a gas-assisted start wood burning fireplace. To start the flame you need to press the trigger that is on the lighter. Then place a bit of tubing or a drinking straw over each pilot hole.

The web source My Gas Fireplace Repair directs placing the meter on the TP and TH terminals. Inspect the log set for leaks. But it would probably cost more and certainly look worse than just buying the replacement part.

Blow down through the straw to clean it out. Secure the burner and grate. Open the gas valve if its closed to restore gas flow.

If your gas fireplace is regularly shutting off after you turn it on its likely that you have a problem with a part of the set-up. With the help of a stainless steel brush and fine-grit sandpaper you can scrub off as much piled up soot as possible. Make certain the pilot is properly hitting your thermocouple just the top of it further down will cause the unit to shut down.

The whole assembly is usually replaced and they usually come at the same price. Gas Fireplace Shuts Off and Pilot Goes Out. It is a vented unit.

The flames blow out but the pilot light stays on then sometimes it will restart on its own. Typically it is a spider we. Change them out or fill them up.

You can heat up your thermocouple thermopile with a lighter for 30-45 seconds and keep it hot. Place the multimeter on both spots the THTP and the TP terminal. Make certain that you dont have glass doors or anything else which impedes the air flow around the valve.

Wipe down all of the areas around the ventless gas logs cleaning it thoroughly.


How To Fix A Gas Fireplace That Keeps Turning Off Vertical Chimney Care


Gas Fireplace Won T Light Fixed Youtube


How To Fix A Blocked Gas Fireplace Youtube


How To Select And Install A Gas Fireplace Log Set Fireplaces Direct Blog


How To Fix A Gas Fireplace That Keeps Turning Off Vertical Chimney Care


What You Should Know About Soot Buildup In A Gas Fireplace In 2022 Gas Fireplace Fireplace Old Fireplace